High-end infusion pump, used for heating infusions, medicines, can be used in ICU room, private room, normal wards.
This bed is with CE approval
Descriptions
* Infusion rate range
* Adjustable drop rate range: 1 /min~400 drops/min
(step: 1 drop /min)
* Adjustable flow rate range: 1ml/h~1200ml/h
(step 0.1ml/h)
* Purge rate: 800ml/h
* KVO rate: 1ml/h (1~300ml/h)
3ml/h (greater than 300ml/h)
* Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
* Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
* Infusion Time range: 1min~9999min (step: 1 min)
* Infusion accuracy: Within ±3% (using calibrated high quality IV set)
Mechanical precision: within ±2%
* Occlusion alarm threshold:
High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
* Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
* NIBP
* Range
* Average deviation: ≤ ±5mmHg
* Standard deviation: ≤ 8mmHg
* Adult
SYS: 40mmHg~280mmHg
MEAN: 20mmHg~240mmHg
DIA: 10mmHg~220mmHg
* Pediatric
SYS: 40mmHg~220mmHg
MEAN: 20mmHg~170mmHg
DIA: 10mmHg~160mmHg
* Neonate
SYS: 40mmHg~135mmHg
MEAN: 20mmHg~110mmHg
DIA: 10mmHg~100mmHg
* Static pressure
Range: 0mmHg~300mmHg
Deviation: 3mmHg
* Resolution: 1mmHg
* NIBP measurement mode
* Manual
* Cycle (automatic):
* Optional interval: 1min, 2min, 3min,4min, 5min, 10min,
* 15min, 30min, 60min, 90min
* Fast: continuous NIBP measurement, interval is 5min
* NIBP alarm
* High pressure alarm: >90mmHg-160mmHg
* Low pressure alarm: <50mmHg-90mmHg
* Accuracy: ±5%
* Overpressure protection
* Adult: 280 mmHg ±10 mmHg
* Pediatric: 237 mmHg ±3 mmHg
* Neonate: 147 mmHg ±3 mmHg
* SpO2
* Range: 0%~100%
* Resolution: 1%
* Accuracy: 70% to 100%, precision is 2%
0% to 69%, undefined
* SpO2 alarm
* Upper limit: 100%
* Lower limit: 90%
* Alarm value accuracy: 3%
* Alarm time accuracy: 2s
* Pulse rate
* Range: 20bpm~300bpm
* Resolution: 1bpm
* Accuracy: 3bpm
* Pulse rate alarm
* Upper limit: 120bpm
* Lower limit: 50bpm (default)
* Alarm value accuracy: 5%
* Alarm time accuracy: 2s
* NIBP Cuff requirement
* Human body contact materials: Waterproof cloth
* Size: 515mm(L)×145mm(W), allowed deviation: ±5%
* SpO2 sensor
* Type: Finger clip type
* Wire length: 3000mm, allowed deviation: ±5%
* Human body contact materials: Silicone
* Size: 188 mm(L)×198 mm(W)×228 mm(H)
* Net weight: 2.5kg
Standard Function:
* 4.3" color TFT LCD screen (LED backlight), with resolution 272×480
* Three working modes: Rate/Time/Volume mode
* Drug library with 210 kinds of medicine
* Storage 1500 history records
* Heating function, suitable for infusing in winter or there is requirement for the fluid medication temperature
* Support multi language display
* A variety of visible and audible alarm, make infusion more safe
* Standard:Drug library, History record, Heating function, Drip detector
Model | SK-EM211 |
Size | 188*198*228mm |
Net Weight | 2.5Kg |